-Before querying the measurements, you have to set an address to the device+All commands include a device address (i.e. C0 A8 01 01 = 192.168.1.1). 
-Else it won't reply to the other commands+Only the device with the specified address will respond. 
-The manual uses an IP as address (192.168.1.1 = C0 A8 01 01)+This allows to query multiple devices on the same UART portone after another, when they have different addresses. 
-No idea why you would set an IP for a UART address.+Thus you have to set the device's address at least once using the 0xA4 command before querying measurements
 +This address will be saved so the next time (even after power down) you can directly query measurements using the address(se) set in the device(s).
  