spark_counter [2015/10/25 18:04] – update attachment links kingkevinspark_counter [2015/10/25 18:40] – add pictures kingkevin
Line 22: Line 22:
   * is powered using 80-260 V AC   * is powered using 80-260 V AC
   * provides a TTL UART port to query these values (or set an alarm so to beep when a provided power threshold is reached)   * provides a TTL UART port to query these values (or set an alarm so to beep when a provided power threshold is reached)
 +
 +{{:spark_counter:dsc02361.jpg?0x200|}}
 +{{:spark_counter:dsc02359.jpg?0x200|}}
  
 The voltage measurement is done over the power input port. The voltage measurement is done over the power input port.
Line 27: Line 30:
 Pass the wire on which you would like to measure the current through the coil, and connect the coil to the power meter. Pass the wire on which you would like to measure the current through the coil, and connect the coil to the power meter.
 A drawing on the back of the device will describe how to connect the wires. A drawing on the back of the device will describe how to connect the wires.
 +
 +{{:spark_counter:dsc02328.jpg?0x200|}}
  
 The meter also provides a UART port to query the measured values. The meter also provides a UART port to query the measured values.
Line 59: Line 64:
 Each command triggers a very loud buzzer beep (same a for the alarm). Each command triggers a very loud buzzer beep (same a for the alarm).
 I removed the pizeo-element to prevent this annoying sound. I removed the pizeo-element to prevent this annoying sound.
 +
 +{{:spark_counter:dsc02344.jpg?0x200|}}{{:spark_counter:dsc02325.jpg?0x200|}}{{:spark_counter:dsc02327.jpg?0x200|}}
  
 The power meter uses a single chip solution, the [[http://www.sdicmicro.com/products.html?ic=SD3004|SDIC microelectronics SD3004]] ({{:spark_counter:sd3004_datasheet_v0.2c.pdf|datasheet}}). The power meter uses a single chip solution, the [[http://www.sdicmicro.com/products.html?ic=SD3004|SDIC microelectronics SD3004]] ({{:spark_counter:sd3004_datasheet_v0.2c.pdf|datasheet}}).
Line 89: Line 96:
 ====== nRF24L01+ ====== ====== nRF24L01+ ======
  
 +{{:spark_counter:dsc02353.jpg?0x150|}}
 {{ :spark_counter:nrf24l01_pinout.jpg?250|nRF24L01+ pinout}} {{ :spark_counter:nrf24l01_pinout.jpg?250|nRF24L01+ pinout}}
  