ea-ps_2084-03b [2015/06/03 21:35] – experiments kingkevinea-ps_2084-03b [2015/06/07 17:46] – add connection table kingkevin
Line 60: Line 60:
  
 ==== connection ==== ==== connection ====
 +
 +=== UT-D02 ===
  
 The DMM comes with an RS232 [[http://www.uni-trend.com/en/product/2014_0626_553.html|UT-D02]] cable. The DMM comes with an RS232 [[http://www.uni-trend.com/en/product/2014_0626_553.html|UT-D02]] cable.
Line 78: Line 80:
   * RS232 signals are inverted compared to UART. This was solved by inverting the signal using an NPN transistor and two resistors.   * RS232 signals are inverted compared to UART. This was solved by inverting the signal using an NPN transistor and two resistors.
  
-More details about the cable and modification is described in this picture:+^ UT-D02 wire ^ CP2102 UART signal ^ PNP ^ 
 +| green | GND | | 
 +| yellow | GND | | 
 +| orange | 5V | | 
 +| | GND | E | 
 +| | 5V + 10kΩ | C | 
 +| brown + 10kΩ | | B | 
 +| | RX | C | 
 + 
 +=== UT-D04 ===
  
 For the second multimeter I used a [[http://www.uni-trend.com/en/product/2014_0626_555.html|UT-D04]] USB cable. For the second multimeter I used a [[http://www.uni-trend.com/en/product/2014_0626_555.html|UT-D04]] USB cable.