 +====== experiments and results ======
 +
 +I've run 5 experiments:
 +  * go from 0 V to 84 V in 0.1 V increments, without any load
 +  * go from 0 V to 84 V at 1.0 A in 0.1 V increments, with a 678 Ω load
 +  * go from 0 V to 11 V at 1.0 A in 0.1 V increments, with a 10.2 Ω load
 +  * go from 0 A to 3 A in 0.1 A increments, with a short
 +  * go from 0 A to 1 A at 10 V in 0.01 A increments, with a 10.2 Ω load
 +
 +After changing a value I've waited 3 seconds for the measurements to stabilized.
 +
 +The measurements and accuracy calculations are available in this {{:ea-ps_2084-03b:accuracy.tar.gz|spreadsheet}}.
 +
 +Here are the resulting graphs:
 +  * go from 0 V to 84 V in 0.1 V increments, without any load
 +{{:ea-ps_2084-03b:voltage-no_load-difference.svg?900}}
 +{{:ea-ps_2084-03b:voltage-no_load-set_accuracy.svg?900}}
 +{{:ea-ps_2084-03b:voltage-no_load-nominal_accuracy.svg?900}}
 +  * go from 0 V to 84 V at 1.0 A in 0.1 V increments, with a 678 Ω load
 +{{:ea-ps_2084-03b:voltage-678_ohms-difference.svg?900}}
 +{{:ea-ps_2084-03b:voltage-678_ohms-set_accuracy.svg?900}}
 +{{:ea-ps_2084-03b:voltage-678_ohms-nominal_accuracy.svg?900}}
 +  * go from 0 V to 11 V at 1.0 A in 0.1 V increments, with a 10.2 Ω load
 +{{:ea-ps_2084-03b:voltage-10_ohms-difference.svg?900}}
 +{{:ea-ps_2084-03b:voltage-10_ohms-set_accuracy.svg?900}}
 +{{:ea-ps_2084-03b:voltage-10_ohms-nominal_accuracy.svg?900}}
 +  * go from 0 A to 3 A in 0.1 A increments, with a short
 +{{:ea-ps_2084-03b:current-short-difference.svg?900}}
 +{{:ea-ps_2084-03b:current-short-set_accuracy.svg?900}}
 +{{:ea-ps_2084-03b:current-short-nominal_accuracy.svg?900}}
 +  * go from 0 A to 1 A at 10 V in 0.01 A increments, with a 10.2 Ω load
 +{{:ea-ps_2084-03b:current-10_ohms-difference.svg?900}}
 +{{:ea-ps_2084-03b:current-10_ohms-set_accuracy.svg?900}}
 +{{:ea-ps_2084-03b:current-10_ohms-nominal_accuracy.svg?900}}
 +
 +As you can see the measured values are most of the time higher than the set values, but within the 0.2 % accuracy (to 84V or 3A).
 +But the actual values displayed by the power supply is way below what is set, and outside of the accuracy, particularly on the low voltages.
 +
 +Conclusion: don't trust the displayed voltage (it's too low), but you can be confident the output is right (except for the very low voltages and currents).