ea-ps_2084-03b
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
ea-ps_2084-03b [2015/05/26 18:36] – measurement part 1 kingkevin | ea-ps_2084-03b [2015/05/27 18:47] – typo kingkevin | ||
---|---|---|---|
Line 33: | Line 33: | ||
* [[http:// | * [[http:// | ||
* [[http:// | * [[http:// | ||
- | * [[http:// | + | * [[http:// |
====== measurement ====== | ====== measurement ====== | ||
Line 51: | Line 51: | ||
The [[https:// | The [[https:// | ||
- | It will set the voltage and current which are set, actual (measured by the power supply), and [[#mutli-meter|measured]] (measured by the DMM) | + | It will set the voltage and current which are set, actual (measured by the power supply), and [[#mutlimeter|measured]] (measured by the DMM) |
- | ===== mutli-meter | + | ===== multimeter |
+ | To measure the output of the power supply I used two [[http:// | ||
+ | These are good multimeters for electronics which you can get [[http:// | ||
+ | More functions and its accuracy are available in the [[http:// | ||
+ | ==== connection ==== | ||
+ | |||
+ | The DMM comes with an RS232 [[http:// | ||
+ | To connect to the PC you need a RS232 to USB converter (are PCs with COM ports still manufactured? | ||
+ | |||
+ | The cheapest RS232 to USB converter one is based on the CH341 chip. | ||
+ | Sadly the 7O1 mode used by the multimeter [[http:// | ||
+ | I also tried the [[https:// | ||
+ | |||
+ | I also has an old ARL3116 based RS232 to USB converter, but there too the mode didn't seem to be supported. | ||
+ | |||
+ | Finally I found a FT232-based RS232 to USB converter. | ||
+ | This is an expensive cable (but good quality), from an evil company, and it worked. | ||
+ | |||
+ | But instead of using it, I decided to connect the cable to a CP2102-based UART to USB converter. | ||
+ | Then you have to keep two things in mind: | ||
+ | * RS232 signals are between -12 to +12 V, while UART uses 0-5 V. This was solved by simply using the 5 V pin from the converter to power the cable. | ||
+ | * RS232 signals are inverted compared to UART. This was solved by inverting the signal using an NPN transistor and two resistors. | ||
+ | |||
+ | More details about the cable and modification is described in this picture: |
ea-ps_2084-03b.txt · Last modified: 2024/01/07 17:49 by 127.0.0.1