busvoodoo [2017/12/22 18:30] – add pictures kingkevinbusvoodoo [2017/12/22 20:51] – [protocols] add pictures kingkevin
Line 87: Line 87:
 The hardware is only designed for signals speeds up to 20 MHz. The hardware is only designed for signals speeds up to 20 MHz.
 The signals can be driven using 3.3 V push-pull mode, or 1.6 to 5.5 V open-drain mode with 2 kOhm embedded pull-up resistors (can be increased using external resistor). The signals can be driven using 3.3 V push-pull mode, or 1.6 to 5.5 V open-drain mode with 2 kOhm embedded pull-up resistors (can be increased using external resistor).
 +
 +{{ :busvoodoo:io_pinout.png?700|I/O pinout}}
  
 ^ protocol ^ support ^ comment ^ ^ protocol ^ support ^ comment ^
Line 97: Line 99:
 | LIN | hardware | | | LIN | hardware | |
 | ISO-7816 | hardware | | | ISO-7816 | hardware | |
-| RS-232 | hardware | with hardware flow control, only in full version | 
-| RS-485 | hardware | no termination resistor, only in full version | 
-| RS-422 | hardware | no termination resistor, only in full version | 
-| CAN | hardware | no termination resistor, only in full version | 
 | 1-Wire | software | | | 1-Wire | software | |
 | MicroWire | software | | | MicroWire | software | |
Line 111: Line 109:
 | cJTAG | software | planned | | cJTAG | software | planned |
  
-note: the status of each protocol support is not documented yet (WiP)+No matter which protocol you are using, the hardware has been designed to provide one additional UART port
  
-no matter which protocol you are using, the hardware has been designed to provide one additional UART port+{{ :busvoodoo:mini_adapter_ports_rscan_pin.jpg?300|RS/CAN pinout}} 
 +The full version also supports additional higher voltage and differential protocols.
  
 +^ protocol ^ support ^ comment ^
 +| RS-232 | hardware | with hardware flow control, only in full version |
 +| RS-485 | hardware | no termination resistor, only in full version |
 +| RS-422 | hardware | no termination resistor, only in full version |
 +| CAN | hardware | no termination resistor, only in full version |
 +
 +
 +note: the status of each protocol support is not documented yet (WiP)
 ===== firmwares ===== ===== firmwares =====